Solar system wiring diagram for a Nigerian home
Tap a part to see how it connects, and switch between day, night and grid to see which way power flows. Sizes come from the home examples. Generic parts, no brands, no prices.
The panels feed the inverter. It runs the home first and charges the battery with what is left over.
Hybrid inverter
Turns DC into the AC your home uses, charges the battery from the panels and the grid, and switches between them.
- Hybrid solar inverter (1). Pure sine wave, 3.5 kVA, 48 V battery system, built-in MPPT solar charger. Surge rating high enough to start your biggest motor.
- Monitoring (1). A Wi-Fi or Bluetooth module for the inverter so you can watch charging and use from your phone, if your inverter supports one.
- Mount it on a solid wall in a ventilated, dry place out of direct sun. Never cover its vents.
- Follow the maker's manual for the order of connecting battery, panels and AC.
- Keep cable runs as short as the manual allows.
Sizing checks for the panel array
The medium home needs 8 panels. They are wired here as 8, because strings need whole panels. The inverter limits are typical for this size, not a real product, so use the compatibility checker with your own datasheet values.
Overall: OK
- Cold open-circuit voltage305.6 V, at most 450 V
Why this matters
Panel voltage rises when it is cold, and is highest at sunrise with no load. Above the inverter's absolute maximum it can be destroyed, so this is the check that matters most. Fewer panels in series lowers it.
- Hot working voltage221.9 V, at least 120 V
Why this matters
Hot panels produce a lower voltage. If the string falls below the tracking window the inverter cannot harvest it, usually in the afternoon heat. More panels in series raises it.
- Cold working voltage255.5 V, at most 400 V
Why this matters
Above the tracking window the inverter cannot follow the maximum power point, so you lose some output on cool mornings. It is not dangerous.
- Working current12.9 A, at most 18 A per input
Why this matters
Parallel strings add their current. Too much current is clipped, which wastes panels, and sustained overload can overheat the input.
- Short-circuit current (with 25% margin)17 A, at most 25 A per input
Why this matters
The inverter must survive the panels' worst-case current, which is the datasheet short-circuit current with a margin for strong sun.
- Array power against input limit3 200 W, up to 4 000 W
Why this matters
A little oversizing is common and loses only a few hours of peak output. Far beyond the input limit is mostly wasted money.
Protection to ask for
- PV isolator and breaker rated for DC, at least 306 V and 17 A.
- Battery DC breaker of about 100 A at 48 V, which is 1.25 times the inverter's maximum battery current of about 65 A, rounded up to a standard size.
- Surge protection on the DC panel side and on the AC side, joined to the earthing system.
Jump to a part
This guide is general information, not engineering, electrical or financial advice. Have a qualified, experienced installer assess your home or business, and follow local safety rules and the supplier's instructions.
Common questions
How do I connect solar panels, an inverter and batteries?
The panels connect to the inverter through a DC isolator and surge protection. The battery connects to the inverter through a DC breaker. The grid or generator goes into the inverter's input, and the inverter's output feeds the board for the circuits you want backed up. Everything is joined to one earthing system. The diagram shows each link.
Why does the diagram use cold voltage?
Solar panels make a higher voltage when they are cold, and the highest voltage of the day is at first light on a cool morning. The inverter has a maximum input voltage that must never be exceeded, so the checks use the coldest morning you are likely to see.
Is this a wiring plan I can follow?
No. It is a teaching diagram with typical values. Your inverter's manual, the datasheets and a qualified installer decide the real design, including cable sizes, breakers and earthing.
Do I need a separate charge controller?
Most home systems today use a hybrid inverter that has the solar charge controller built in, as in this diagram. Older or smaller systems use a separate controller between the panels and the battery.