Solar system size for a small, medium or large home
Pick the size closest to your home. See the inverter, battery and panels it needs, and the parts around them. No prices.
A one or two bedroom flat, a small shop or an office with a few staff.
- Inverter
- 1 kVA
- Battery system
- 24 V
- Solar panels
- 4 × 400 W
- Energy a day
- 4.2 kWh
What it runs (about 4 hours of backup)
- 6 × LED lights
- 2 × Standing or ceiling fans
- 1 × Television
- 1 × Refrigerator
- 1 × Laptop
- 1 × Wi-Fi router
- 2 × Phone chargers
About 535 W if everything is on, and 728 W for a moment when the biggest motor starts.
The main parts
Hybrid solar inverter
1 kVA, 24 V
What to look for
Pure sine wave, 1 kVA, 24 V battery system, built-in MPPT solar charger. Surge rating high enough to start your biggest motor.
Batteries: lithium
1 × 24 V bank of about 123 Ah
What to look for
About 2.9 kWh of lithium (LiFePO4) at 24 V, which gives about 2.12 kWh of backup. Must be compatible with your inverter.
Batteries: tubular lead-acid
2 × 12 V 200 Ah
What to look for
Wired in series to 24 V. More batteries than lithium for the same backup, because lead-acid should only be drained about halfway.
Solar panels
4 × 400 W
What to look for
About 1.6 kWp in total, which makes roughly the 4.18 kWh a day this home uses on an average sunny day. Needs about 8 m² of shade-free roof. Check the total against the inverter's maximum solar input.
Wiring, protection and the rest (9 items)
Panel mounting · 1 set for 4 panels
Aluminium rails, clamps and roof fixings rated for Nigerian wind, with corrosion protection near the coast.
PV cable and MC4 connectors · As the roof run needs
UV-resistant, double-insulated solar cable (4 or 6 mm² depending on length and the panel wiring) with matching MC4 connectors. Your installer confirms the size.
DC isolator and breakers · 1 set
A DC isolator and breaker on the panel side, and a DC breaker or fuse between battery and inverter rated above about 38 A.
Battery cables and busbars · 1 set
Thick, short battery cables sized for about 38 A at 24 V. Long thin cables overheat.
Distribution board and AC breakers · 1
A separate board for the circuits the inverter will back up, with correctly rated breakers.
Surge protection · 1 DC and 1 AC device
Surge protection devices on the panel side and on the AC side, because lightning and grid surges are common.
Earthing · 1 set
An earth rod and earth cable for the frame, inverter and surge protection.
MonitoringOptional · 1
A Wi-Fi or Bluetooth module for the inverter so you can watch charging and use from your phone, if your inverter supports one.
Installation and commissioning · 1
Labour, testing, handover and a written warranty. Ask who fixes problems after installation.
A three bedroom home with a fridge and freezer and a water pump, or a busy shop.
- Inverter
- 3.5 kVA
- Battery system
- 48 V
- Solar panels
- 8 × 400 W
- Energy a day
- 9.3 kWh
What it runs (about 8 hours of backup)
- 12 × LED lights
- 4 × Standing or ceiling fans
- 2 × Television
- 1 × Refrigerator
- 1 × Chest freezer
- 2 × Laptop
- 1 × Wi-Fi router
- 4 × Phone chargers
- 1 × Water pump (0.75 HP)
About 1 855 W if everything is on, and 2 984 W for a moment when the biggest motor starts.
The main parts
Hybrid solar inverter
3.5 kVA, 48 V
What to look for
Pure sine wave, 3.5 kVA, 48 V battery system, built-in MPPT solar charger. Surge rating high enough to start your biggest motor.
Batteries: lithium
3 × 48 V 100 Ah units (about 5 kWh each)
What to look for
About 11.5 kWh of lithium (LiFePO4) at 48 V, which gives about 8.31 kWh of backup. Must be compatible with your inverter.
Batteries: tubular lead-acid
8 × 12 V 200 Ah
What to look for
Wired in series to 48 V. More batteries than lithium for the same backup, because lead-acid should only be drained about halfway.
Solar panels
8 × 400 W
What to look for
About 3.2 kWp in total, which makes roughly the 9.25 kWh a day this home uses on an average sunny day. Needs about 16 m² of shade-free roof. Check the total against the inverter's maximum solar input.
Wiring, protection and the rest (9 items)
Panel mounting · 1 set for 8 panels
Aluminium rails, clamps and roof fixings rated for Nigerian wind, with corrosion protection near the coast.
PV cable and MC4 connectors · As the roof run needs
UV-resistant, double-insulated solar cable (4 or 6 mm² depending on length and the panel wiring) with matching MC4 connectors. Your installer confirms the size.
DC isolator and breakers · 1 set
A DC isolator and breaker on the panel side, and a DC breaker or fuse between battery and inverter rated above about 65 A.
Battery cables and busbars · 1 set
Thick, short battery cables sized for about 65 A at 48 V. Long thin cables overheat.
Distribution board and AC breakers · 1
A separate board for the circuits the inverter will back up, with correctly rated breakers.
Surge protection · 1 DC and 1 AC device
Surge protection devices on the panel side and on the AC side, because lightning and grid surges are common.
Earthing · 1 set
An earth rod and earth cable for the frame, inverter and surge protection.
MonitoringOptional · 1
A Wi-Fi or Bluetooth module for the inverter so you can watch charging and use from your phone, if your inverter supports one.
Installation and commissioning · 1
Labour, testing, handover and a written warranty. Ask who fixes problems after installation.
A four or five bedroom house, or a small business, that also runs air conditioners.
- Inverter
- 7.5 kVA
- Battery system
- 48 V
- Solar panels
- 17 × 400 W
- Energy a day
- 20.4 kWh
What it runs (about 10 hours of backup)
- 20 × LED lights
- 6 × Standing or ceiling fans
- 3 × Television
- 2 × Refrigerator
- 1 × Chest freezer
- 3 × Laptop
- 1 × Wi-Fi router
- 6 × Phone chargers
- 2 × Air conditioner (1 HP inverter)
- 1 × Water pump (0.75 HP)
About 4 195 W if everything is on, and 5 156 W for a moment when the biggest motor starts.
The main parts
Hybrid solar inverter
7.5 kVA, 48 V
What to look for
Pure sine wave, 7.5 kVA, 48 V battery system, built-in MPPT solar charger. Surge rating high enough to start your biggest motor.
Batteries: lithium
6 × 48 V 100 Ah units (about 5 kWh each)
What to look for
About 28 kWh of lithium (LiFePO4) at 48 V, which gives about 20.18 kWh of backup. Must be compatible with your inverter.
Batteries: tubular lead-acid
20 × 12 V 200 Ah
What to look for
Wired in series to 48 V. More batteries than lithium for the same backup, because lead-acid should only be drained about halfway.
Solar panels
17 × 400 W
What to look for
About 6.8 kWp in total, which makes roughly the 20.39 kWh a day this home uses on an average sunny day. Needs about 34 m² of shade-free roof. Check the total against the inverter's maximum solar input.
Wiring, protection and the rest (9 items)
Panel mounting · 1 set for 17 panels
Aluminium rails, clamps and roof fixings rated for Nigerian wind, with corrosion protection near the coast.
PV cable and MC4 connectors · As the roof run needs
UV-resistant, double-insulated solar cable (4 or 6 mm² depending on length and the panel wiring) with matching MC4 connectors. Your installer confirms the size.
DC isolator and breakers · 1 set
A DC isolator and breaker on the panel side, and a DC breaker or fuse between battery and inverter rated above about 139 A.
Battery cables and busbars · 1 set
Thick, short battery cables sized for about 139 A at 48 V. Long thin cables overheat.
Distribution board and AC breakers · 1
A separate board for the circuits the inverter will back up, with correctly rated breakers.
Surge protection · 1 DC and 1 AC device
Surge protection devices on the panel side and on the AC side, because lightning and grid surges are common.
Earthing · 1 set
An earth rod and earth cable for the frame, inverter and surge protection.
MonitoringOptional · 1
A Wi-Fi or Bluetooth module for the inverter so you can watch charging and use from your phone, if your inverter supports one.
Installation and commissioning · 1
Labour, testing, handover and a written warranty. Ask who fixes problems after installation.
Common questions
What size solar system does a house in Nigeria need?
It depends on what you run and for how long. As a guide, a small home with lights, fans, a TV and a fridge needs about a 1 kVA inverter. A three bedroom home with a freezer and a pump needs about 3.5 kVA, and a large home that runs air conditioners needs about 7.5 kVA. Use the calculator for your own appliances.
Why do you not show prices?
Prices in Nigeria move with the exchange rate, so a printed price goes out of date quickly. This page shows sizes and equipment so you can ask for like-for-like quotes. See our cost guide for what drives the price.
Can I run an air conditioner on solar?
Yes, but air conditioners are the biggest load by far and they set the size of the whole system. Many people run them mainly in the daytime on solar and keep the battery for lights, fans and the fridge at night.
Should I choose lithium or lead-acid batteries?
Each example shows both. Lithium needs fewer units and can be used deeper. Tubular lead-acid costs less per unit but you need more of them because they should only be drained about halfway.
Are these designs ready to install?
No. They are planning examples. An experienced installer must check your roof, your wiring, your inverter's limits and local rules before anything is bought.
This guide is general information, not engineering, electrical or financial advice. Have a qualified, experienced installer assess your home or business, and follow local safety rules and the supplier's instructions.